EMC VNX hardware overview

The VNX series is the family of midrange-to-enterprise products. It unifies file-based and block-based offering into a single product.

In this post I would like to describe hardware components a little bit more.

Lets take VNX5500 as an example:

Figure 1. Block and File (Unified) VNX5500 platform

Figure 1. Block and File (Unified) VNX5500 platform

Disk-processor enclosure (DPE)

The enclosure is 3U in size and houses each storage processor and the first tray of disk. It can be found on the figure above with 25 (2.5 inch) disks. Let’s take a look at rear view:

Figure 3. Back view of DEP with SP A (right) and SPB (left)

Figure 2. Back view of DEP with SP A (right) and SPB (left)

Storage processors (SPs)

SP support block data with UltraFles I/O technology – supporting Fibre Channel, iSCSI and FCoE protocols. Storage Processors provide access for all external hosts and the file side of the VNX array.

Figure 4.  Closeup of DPE-based storage processor

Figure 3. Closeup of DPE-based storage processor

On above example SPs are located in Disk Processor Enclosure (DPE).

Storage processor enclosure (SPE)

The enclosure is 2U in size and houses each storage processor. It can be found in VNX5700 and VNX7500 models, support maximum of 500 (VNX5700) and 1,000 drives (VNX7500)

 Control Station

Control Station are 1U in size and provide management functions to the file-side components (referred to as Blades or Data Movers). The CS is responsible for Blade failover. To provide HA Control Station might be configured with a matching secondary CS.

Figure 4. Control Station rear view

Figure 4. Control Station rear view

Data Mover

Data Mover (or Blade) access data from the back-end and provide host access using the same UltraFlex I/o technology that supports NFS, CIFS, pNFS protocols. The Data Movers in each array are scalable and provide redundancy.

Data Mover Enclosure (DME)

The DME is 2U in size and houses the Data Movers (Blades).  The DME is similar in front to SPE and is used on all VNX models that support file.

Figure 5. DME rear view

Figure 5. DME rear view

4 thoughts on “EMC VNX hardware overview

  1. Hi,

    I was asked a interview question if it mattered to have all drive types in a separate tier or can they be mixed in each DAE? Basically, they wanted to know if we can have or should have some flash SSDs in each tier. I told them no wince fast VP will automatically move the data accordingly to the application I/O needs. Does this make sense?